| ADS
Technologies
See More Performance
at High Temperatures Enabled by Low Power Design 8
Hours, Full Operation case study This PDA needed to operate a full shift
on one charge. Plus, it had to charge and run on 'any battery that would fit' Leverage
the Low Power Advantage to Run on CAT V See what IEEE spec 802.3 could
mean to you. Why
use RISC instead of x86 CISC? Giving up Milliwatt Power should not mean
giving up MIPS Power |
RISC
IEC61508
Applications
Applied
Data Systems products have several features that make it simple
to engineer functionally safe systems according to IEC61508. These
features include advanced power management, including fail-safe
startup and shutdown; self check and diagnostic hardware and software;
third-party certified extended temperature and vibration specifications;
extended MTTF from single board' design and specially tested and
robust operating system builds.
Power Management:
ADS System can be equipped with a 'super cap' that allows safe
shutdown and restart. "Hot", "Warm", "Cold"
and "Frozen" restarts can be programmed based on how long
power was off. When the device senses a power-failure of a predetermined
length it can switch to power off its capacitor. It can then have
up to several seconds to run power shutdown routines, inspect the
status of the process, notify other systems, and shut down its I/O
in a controlled and predetermined manner. The system can also save
the state of the process, either in nonvolatile flash or battery
backed up RAM to allow subsequent diagnostics and orderly startup.
While in power failure the systems can be kept in 'sleep' mode for
days off a small battery, or- with information saved onto flash,
can simply shut down. In the shut down state some of the ADS systems
have a Real Time Clock with an on-chip battery backup good for 10+
years. This means that when power returns the system can return
to operation based on how long it was down. For example, after and
short power failure of a few seconds, pumps and motors may still
be spinning and return to operation must be based on this situation.
Self-Check
Most ADS Systems have a onboard 8-bit microprocessor that can
be programmed to work as a watchdog or activity timer. When used
in connection with a OS-dependant, scheduled task this can be a
very effective monitor of system health. This microprocessor is
a fully separate system that continues to run no matter what happens
to the main CPU. It has its own dedicated GPIO to signal main CPU
failure. Within the OS, ADS systems can be built to have a full
suite of OS self-monitoring, including measures for CPU load, task
execution, com port activity, memory usage and event logging. Upon
detection of any potential error situation, (for example a DOS attack
on a network port or an approaching overload of the CPU), the system
can reconfigure itself or cancel some tasks to take 'fail safe'
or 'fail soft' action.
Extended Environmental Specs.
Using a procedure from CALCE labs at the University
of Maryland, ADS can design circuits for extreme environments. We can and have
met various specifications for SAE and military spec use. On request, these specifications
can be 3rd party certified. This means that a safety system could keep working
even if there is an emergency that causes high temperature or high-vibration conditions.
Reliable Single Board Design ADS systems tend to include a great
deal of I/O on an single board, eliminating connectors, cables and jumpers, a
perennial source of failure. This, coupled with the robust sentimental specs,
give the ADS systems a MTTF of 40,000 hours or more. It is important to remember
this is a system spec, not the spec for a single card that gets combined with
three or four other cards to provide equivalent I/O. If a redundant or triplex
configuration is desired, ADS systems have a variety of high speed parallel or
serial interface options that can keep process databases synchronized between
computers. Special OS System Builds. For applications requiring
safety, ADS routinely supplies special OS builds with all components not germane
to the application removed. Also, all code provided by ADS is stress-tested and
run for extended periods to disclose any memory leaks or systematic faults. If
specified by the customer, these systems can be submitted for 3rd party verification
of conformance to OS spec.
In summary, an ADS System provides a secure framework to build an
IEC-61508 functionally safe system. The watchdog timers, power back
ups, environmental housings used for other systems are built into
an ADS system resulting in lower cost, more straightforward engineering
and more robust system design.
For